Publication
2755-2.63
The following Allen-Bradley software is needed to use the procedure
described in this application note:
Bulletin 6200 development software for the PLC-5, to run in the
personal computer
Terminal Emulation software for a personal computer, to
configure the 2760-RB
2755-ASN W
indows-Based Of
fline Program Software to
configure the AdaptaScan reader
This document refers to the following publications, which should be
available for reference while working through this application note:
Publication Number Title
1785-XXX User Manual for your PLC-5
6200-XXX Programming Manual for your PLC-5
2755-837 AdaptaScan Bar Code Readers Installation Manual
2755-838 AdaptaScan Configuration Software User Manual
2760–ND001 2760–RB User Manual
2760-2.16 2760-SFC1 Protocol Cartridge Manual
2760-2.19 2760-SFC2 Protocol Cartridge Manual
Use the following table as a configuration guideline when using the
examples shown in this document.
2760-RB In Use
PLC-5, -15, -25,
etc.
New Generation PLC-5
(Series A, Rev. C or above only)
Series A, Rev
. G or
below
Follow example
PLC program as
Set BT Compatibility Bit S26/4 while in
program mode. Use example PLC program
shown on page 9.
Series A, Rev H or
Above
PLC program as
shown on page 9.
Add ladder logic using IIN update of RB.
BTR must be before ‘BTW. Refer to
page 10.
Software Requirements
Related Publications
PLC 5 Compatibility