Publication 2755-2.63
AdaptaScan Reader to a PLC-5
Using RS-232/ASCII Protocol with
the 2760–RB Module
and the 2760-SFC1 and -SFC2
Protocol Cartridge
The AdaptaScan-SN3, -SN5 or -SN8 bar code reader may be
configured to communicate with the 2760-RB interface module via
“dumb terminal protocol” RS-232, using the 2760-SFC1 or -SFC2
protocol cartridge.
This document includes cable diagrams and configuration
information for the AdaptaScan readers. It also includes an example
PLC-5 program which is needed to establish communication from
the PLC to the 2760-RB.
The following Allen-Bradley hardware is needed to use the
procedure described in this application note:
2755-SN3, -SN5, or -SN8 AdaptaScan reader and related
manuals.
2760-RB interface module in a 1771 rack with a PLC-5
processor
2760-SFC1 or –SFC2 protocol cartridge
Personal computer or VT 100 type terminal to configure the
2760-RB
Appropriate cables to program the PLC-5 and to configure the
2760-RB interface module and the AdaptaScan reader. Refer to
hardware manuals for cable requirements.
Catalog Number 1784-KT or equivalent card installed in the
computer to enable you to program the PLC-5.
Application
Note
Overview
Hardware Requirements
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Protocol Cartridge

Publication 2755-2.63AdaptaScan Reader to a PLC-5Using RS-232/ASCII Protocol withthe 2760–RB Module and the 2760-SFC1 and -SFC2Protocol CartridgeThe A

Seite 2 - PLC 5 Compatibility

10Publication 2755-2.63Using the 2760-RB, Revision H or Above, with the NewGeneration PLC5When the 2760-RB, Revision H or above, is used with the N

Seite 3 - Configuration

11Publication 2755-2.63CablingCable 1 must be constructed to connect a configuration terminal tothe 2760-RB Module Configuration port.Cable 2 must

Seite 4 - PLC-5 Program

PLC-5 is a registered trademark of Allen-Bradley Co., Inc., a Rockwell International CompanyAdaptaScan, PLC-5/30, PLC-5/40 and PLC-5/60 are trademarks

Seite 5 - Configuring the 2760-RB

2Publication 2755-2.63The following Allen-Bradley software is needed to use the proceduredescribed in this application note:• Bulletin 6200 develop

Seite 6 - 2755-2.63

3Publication 2755-2.63The 2760-RB configuration example includes sample configurationscreens and DIP switch settings needed to establish communicat

Seite 7

4Publication 2755-2.63PLC-5 ProgramThe sample ladder logic listing below instructs the PLC-5 to:Rung 2:0 – Read AdaptaScan data from the RB module

Seite 8

5Publication 2755-2.63Configuring the 2760-RB1. Set all 2760-RB module DIP switches to Off.2. Connect the smart cable to the Configuration port of

Seite 9 - Sample PLC Program

6Publication 2755-2.632755-SN3, -SN5, -SN8 AdaptaScan Reader ConfigurationThe AdaptaScan Offline Programmer configuration shows only thescreens nee

Seite 10 - Generation PLC5

7Publication 2755-2.63The Serial Port dialog defines communication parameters (RS-232/RS-485/ RS-422) and protocols (ASCII, DH-485, DF1) for therea

Seite 11 - 25-pin D male RS-232

8Publication 2755-2.63The Message dialogs define the format and content of message datasent to the host by the reader when bar codes are decoded. T

Seite 12 - With major offices worldwide

9Publication 2755-2.63And when Edit is selected in the Message Field screen, this dialogappears:A sample PLC program appropriate for using a PLC 5/