Seitenansicht 64
5–4 Communication Setup (Synapse Cable)
Publication 2755-6.4
Setting RS-232 Synapse Cable Options (Continued)
Parity
Set the parity of each ASCII coded character that is transmitted.
Make sure the parity matches the requirements of the host. The
selections are:
Odd
Even
Mark (parity bit always set to 1)
Space (parity bit always set to 0)
None (default)
Check Parity
When enabled, the scanner checks the parity bit.
Number of Stop Bits
The stop bit marks the end of each character transmitted. Set the
number of stop bits to match the host device. The selections are:
1 Stop Bit (default)
2 Stop Bits
Data Bits
Determines the number of data bits for each ASCII character. The
selections are:
7 data bits
8 data bits (default)