Seitenansicht 63
Pin Assignments
Appendix D
D8
Input Voltage
(all rated load conditions)
90 to 132V AC
180 to 264V AC
Input Surge Current
(115V AC, coldstart, peak current)
32 A
Input Frequency Range
47Hz to 440Hz
Input Line Regulation
(low line to higher, full load)
+0.3% to all outputs
Output Power Range
10
o
C (50
o
F)
20W to 100W
Overvoltage Protection Threshold
+5V output: 6.25C +0.75V
Power Limit Point
(all line and load conditions)
140W minimum
Transient Response
+5 output, 5A to 10A load change: 50mV peak transient setting to within
0.5% of regulation band 1ms
+12V and +24 outputs, 2A to 4A load change: 100mV peak transient setting
to within 0.5% at regulation band 1ms